summaryrefslogtreecommitdiff
path: root/fw/prj.conf
diff options
context:
space:
mode:
authorxengineering <me@xengineering.eu>2025-03-21 22:07:26 +0100
committerxengineering <me@xengineering.eu>2025-03-21 22:07:26 +0100
commitfcbd6ac3415d4a122d21b2e379ccf170620f45da (patch)
tree9d13560f540ce89a737192f731bdcfeabb76d899 /fw/prj.conf
parent5f457c4786b270f0918294b09f32c484f165e2ef (diff)
downloadiot-contact-fcbd6ac3415d4a122d21b2e379ccf170620f45da.tar
iot-contact-fcbd6ac3415d4a122d21b2e379ccf170620f45da.tar.zst
iot-contact-fcbd6ac3415d4a122d21b2e379ccf170620f45da.zip
fw: syslog: Add static syslog logging
Network-based logging via the syslog protocol allows to log from many IoT devices to a central log server. This makes reading logs way easier. Choosing UDP removes the need for logic keeping a state. Maybe dropped packages are acceptable for the use case but should be rare anyway.
Diffstat (limited to 'fw/prj.conf')
-rw-r--r--fw/prj.conf12
1 files changed, 12 insertions, 0 deletions
diff --git a/fw/prj.conf b/fw/prj.conf
index 9c84c48..9ac1b51 100644
--- a/fw/prj.conf
+++ b/fw/prj.conf
@@ -7,3 +7,15 @@ CONFIG_SHELL_PROMPT_UART="[iot-contact] "
CONFIG_NETWORKING=y
CONFIG_NET_SHELL=y
+CONFIG_NET_SOCKETS=y
+
+CONFIG_LOG=y
+CONFIG_LOG_BACKEND_NET=y
+CONFIG_LOG_BACKEND_NET_SERVER="[2001:db8::2]:514"
+CONFIG_LOG_MODE_DEFERRED=y
+
+# static IP address configuration is currently required for successful syslog
+CONFIG_NET_CONFIG_SETTINGS=y
+CONFIG_NET_CONFIG_NEED_IPV6=y
+CONFIG_NET_CONFIG_MY_IPV6_ADDR="2001:db8::1"
+CONFIG_NET_IF_UNICAST_IPV6_ADDR_COUNT=3